发电厂石家庄风机常见振动故障及处理(1)
作者:石家庄风机 日期:2014-10-13 浏览:1878
摘要: 针对发电厂石家庄风机常见的振动故障, 分析不同原因引起的石家庄风机振动故障特征。以不平衡故障、松动故障、轴承异常故障以及石家庄风机叶片积灰故障的处理实例, 给出了上述振动故障的处理措施, 以消除故障保证石家庄风机尽快投入生产运行。
关键词: 石家庄风机; 振动故障; 诊断; 处理
Vibration Fault of Blower Fan in Power Plant and the TreatmentYING Guang-yao1, WU Bin2, DONG Yi-hua1, MA Si-cong1(1. Z(P)EPC Electric Power Research Institute, Hangzhou 310014, China;2. Zhejiang Zheneng Power Generation Co. Ltd, Ningbo Zhejiang 315208, China)bAbstract: Aiming at common vibration faults of blower fan in power plant, the paper analyzes characteristicsof vibration faults of blower fan due to different reasons. By taking treatment on unbalance, loosening, abnormalbearing and soot deposit on blades as examples, the paper proposes measures to cope with above faultsso that the blower fan can be put into operation as soon as possible.
Key words: blower fan; vibration fault; diagnosis; treatment
发电厂石家庄风机出现故障或事故时, 会引起发电机组出力降低或停运。而石家庄风机运行中出现最多、影响最大的故障就是振动, 因此, 当出现振动故障时, 尤其是在故障预兆期内, 迅速做出正确的诊断, 对保障机组安全运行具有重要意义。
目前, 大型发电厂主要采用轴流式石家庄风机, 炉侧的一次石家庄风机、送石家庄风机和引石家庄风机是振动测试的重点。石家庄风机振动一般以振动烈度为监测和考核指标, 发电厂可以根据制造厂家的建议设定保护定b值, 如某厂送石家庄风机(型号: ASN-2875/1250)、一次石家庄风机(型号: AST-1812/1250)报警定值为5.6 mm/s,跳机定值为6.3 mm/s; 引石家庄风机(型号: AN35e6)报警定值为4.6 mm/s, 跳机定值为7.1 mm/s。
1 石家庄风机厂常见振动故障特征分析
1.1 质量不平衡故障
在现场发生的石家庄风机轴承振动中, 属于转子质量不平衡的振动占多数。造成转子质量不平衡的原因主要有: 叶轮(主要是叶片)磨损不均匀或腐蚀; 主轴局部高温使轴弯曲; 叶轮检修后未找平衡; 叶轮强度不足造成叶轮开裂或局部变形; 叶轮上零件松动或连接件不紧固。
转子质量不平衡引起的振动有以下特征:
(1)质量不平衡引发的振动在典型频谱上出现与旋转频率相同的一倍频分量(基频分量)。在对质量不平衡的诊断中, 不要过多地关注含有哪些频率成分, 而要注意基频分量是否占主导地位。若基频分量占通频的70%以上, 就可以诊断为强迫振动。
(2)轴流式石家庄风机的水平方向刚度最弱, 因此振动值以水平方向为最大, 而轴向很小。
(3)在转速一定时, 振幅和相位是稳定的。当不平衡一定时, 离心力只跟转速有关, 因此振动只是转速的单值函数。即当转速一定时, 振动也是稳定的,对负荷变化也不敏感。由于振动的影响因素很多, 绝对的稳定是不存在的, 如果振幅的变化范围在其平均值的±10%之内, 相位变化在其平均值的±10°之内,可认为是稳定的。
(4)多次启动振动有再现性。对于质量不平衡量而言, 多次启动后测量到的振动数据应该很接近。质量不平衡量与有些故障的区别仅仅依靠一次启动是难以分清的。
(5)可以排除松动、刚度等因素, 不平衡振动的大小不仅与不平衡量有关, 还与自身的特性(刚度、阻尼、固有频率)有关。如果系统的刚度过低(螺栓有松动), 或者机组在共振区工作, 将会使不平衡的灵敏度提高[ 1 ]。